Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13570832

- Product Categories
- Friendly Links
Information Name: | Imports clip-dynamic flow balance valve |
Published: | 2014-11-03 |
Validity: | 366 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Imports clip-dynamic flow balance valve America Tours valve (TOOE) Introduction: TOOE (Tours), headquartered in Cupertino (Cupertino), California, USA, is a diversified manufacturing and service company. TOOE subsidiary responsible for operating its development centers in China, India and Japan and other Asia-Pacific countries as well as representative offices. TOOE located in Hong Kong and Taiwan (collectively, TOOE China / Tours China) in both China's wholly owned subsidiary. Which is located in Taiwan, a subsidiary of US town in Changhua County, Taiwan Province, Chang Mei Road Sec features a processing plant. Shanghai gold yeah Valve Co., Ltd. as TOOE China's duly authorized agent, solely responsible for the promotion of products in the Tours region of mainland China, sales, technical support and related services have been working. Authorization Number: TE05-86-021 America Tours valve (TOOE) Product: TOOE fluid control valve offers a complete solution for building pipelines and other infrastructure. Major manufacturing balancing valve, electric valve. Valves: ① static balance, static balancing valves, digital lock balance valve, flow balancing valves, manual balancing valves; ② dynamic balancing valve, dynamic flow balance valve, electric control valve dynamic equilibrium, dynamic balance of electric two-way valve; ③ Self-flow balance valve, self-pressure control valve, self-operated pressure balance valve, self-pressure bypass valve; ④ electronic dynamic flow balance valve, the temperature difference between the electronic dynamic balancing valve, electronic dynamic pressure control valve , electronic dynamic equilibrium electric control valve. Electric valve: ① electric two-way valve, the electric two-way valve, electric control valve, electric two-way valve, the electric two-way valve; ② electric three-way valve, electric mixing valve, electric three-way valve. Product Name: Imported clip-on dynamic flow balance valve Product Model: TE118 Specifications: DN50-DN800 product pressure: 1.6MPa, 2.5MPa Material: cast iron, ductile iron, steel, stainless steel Suitable medium: water, oil, ethylene aqueous alcohol distributor in China: Shanghai gold yeah Valve Co., Ltd. Flange dynamic flow balance valve Product Overview: Dynamic Flow Control Valves are automatically change the drag coefficient system conditions (pressure) changes according to the pressure within a certain range, you can effectively by maintaining a constant flow, that is, when the pressure valve before and after the increase, small movements by automatically shutting the valve to maintain the flow does not increase, and vice versa, when the pressure decreases, the valve automatically open a large, traffic still remains constant, however, when the pressure is less than or greater than the normal operating range of the valve, which after all can not provide additional pressure head, when the valve reaches the fully open or fully closed position the flow is still lower than the set flow rate can not control flange or high dynamic Flow Control Valves Benefits Features: ① fixed valve gall structure; ② Axial design; ③ standard measurement port can be connected to a variety of flow test equipment; ④ traffic control error: ± 5% dynamic flow balance valve flange Technical parameters: ① Nominal Diameter: DN50-DN800② nominal pressure: PN10, PN16, PN25③ Working temperature: -10 ℃ -120 ℃ ④ Connection: DIN flange DINEN1092-2⑤ valve guts material: stainless steel (304-2B) ⑥ spring material: stainless steel (1Cr18Ni9) Flange dynamic flow balance valve Dimensions: Type A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) Weight (kg) TE118 DN50 99 125 165 38 239 218 16 TE118 DN65 118 145 185 38 239 218 19 TE118 DN80 132 160 200 38 239 218 22 TE118 DN100 156 190 235 38 365 270 38 TE118 DN125 184 220 270 38 365 295 46 TE118 DN150 211 250 300 38 410 354 66 TE118 DN200 274 ??310 360 38 435 416 96 TE118 DN250 330 370 425 38 456 488 128 TE118 DN300 389 430 485 38 466 564 187 TE118 DN350 448 490 555 38 479 700 249 TE118 DN400 503 550 620 38 504 790 356 TE118 DN450 548 640 670 38 517 800 418 TE118 DN500 609 660 730 38 520 880 518 TE118 DN600 720 770 845 38 554 1050 718 TE118 DN800 928 990 1085 38 557 1260 865 Flange dynamic flow balance valve differential pressure and flow range: Model pass through DN (mm) Pressure tolerance range (kpa) flow range (m3 / h) Maximum number of valves guts (a) TE118 50 15-150 3.2-30 1 22-210 4.0-36 33-330 5.0-46 90-900 8.0-75 TE118 65 15- 150 3.2-30 1 22-210 4.0-36 33-330 5.0-46 90-900 8.0-75 TE118 80 15-150 3.2-30 1 22-210 4.0-36 33-330 5.0-46 90-900 8.0-75 TE118 100 15-150 3.2-60 2 22-210 4.0-72 33-330 5.0-92 90-900 8.0-150 TE118 125 15-150 3.2-150 3 22-210 4.0-180 33-330 5.0-138 90- 900 8.0-225 TE118 150 15-150 3.2-150 5 22-210 4.0-180 33-330 5.0-230 90-900 8.0-375 TE118 200 15-150 3.2-240 8 22-210 4.0-288 33-330 5.0 -368 90-900 8.0-600 TE118 250 15-150 3.2-390 130 22-210 4.0-468 33-330 5.0-598 90-900 8.0-975 TE118 300 15-150 3.2-600 20 22-210 4.0-720 33-330 5.0-920 90-900 8.0-1500 TE118 350 15-150 3.2-690 23 22-210 4.0-828 33-330 5.0-1058 90-900 8.0-1725 TE118 400 15-150 3.2-900 30 22- 210 4.0-1080 33-330 5.0-1380 90-900 8.0-2250 TE118 450 15-150 3.2-1110 37 22-210 4.0-1332 33-330 5.0-1702 90-900 8.0-2775 TE118 500 15-150 3.2- 1410 47 22-210 4.0-1692 33-330 5.0-2162 90-900 8.0-3525 TE118 600 15-150 3.2-1920 64 22-210 4.0-2304 33-330 5.0-2944 90-900 8.0-4800 TE118 800 15 -150 3.2-2850 5.0-1370 90-900 33-330 9522-210 4.0-3420 8.0-7125 Flange dynamic flow balance valve related products: threaded dynamic flow balance valve / Wafer Dynamic Flow Control Valves / threaded Dynamic Balance Electric two-way valve / flange dynamic equilibrium electric control valve ............................................................................................................ ....................................... Valves Overview: Valves (Balancing Valves) is a special feature of the valve, it has good flow characteristics, there is indication of the valve opening, and with the opening of the locking device in flow measurement manometry small valve. Using a dedicated smart meter, enter the valve opening value model and, according to the measured pressure signal can directly show the value of the flow through the flow balancing valve, balance valve as long as the user entry in each branch and fitted with the appropriate specifications, and with a special one-time debugging smart meter, you can enable the user traffic reaches the set value. In the central heating or central air conditioning, hot water or cold water pipe network by water conservancy delivered to individual users. A system in accordance with the design requirements for an ideal running individual users are able to obtain design water flow, to meet user requirements for indoor temperature comfort and energy efficiency requirements of system operation, to avoid customer complaints and energy waste. Such a system is to achieve a balance of water conservancy system, otherwise, is called hydraulic imbalance imbalance or hydraulic system. Balancing valve in the hydraulic conditions, play a dynamic and static balance adjustment valve. Such as: static balance, dynamic balancing valve. Also known as static balance: balance valve, manual balancing valves, digital lock balance valve, double-regulating valve, it is by changing the valve and valve seat gap (opening), to change the resistance to flow through the valve in order to achieve The purpose of adjusting the flow rate, and its role is to drag the object system, new water can be allocated in proportion to the balance of design calculations, each branch simultaneously sliding scale, and still meet the needs of some of the current traffic load under climate needs, from to the heat balance. Dynamic balancing valve into a dynamic flow balance valve, dynamic pressure balance valve, self-self-pressure control valve and so on. Also known as Dynamic Flow Control Valves: operated flow control valve, self-balancing valve, constant flow valves, automatic balancing valves, etc., it is now, according to system conditions (pressure) changes automatically changes the drag coefficient, at a certain pressure within the range, the flow rate can be effectively controlled by maintaining a constant value, i.e., when the pressure difference before and after the valve is increased by small movements automatically close the valve to maintain the flow rate does not increase, the contrary, when the pressure decreases, the valve Automatic open big, to maintain a constant flow rate after the names, however, when the pressure is less than or greater than the normal operating range of the valve, it is after all not provide additional pressure head, then hit the valve fully open or fully closed position to set the flow rate is still higher than low or high flow rate can not be controlled. Dynamic pressure balance valve, also known as: self-pressure control valves, pressure controllers, regulators variable synchronizer, pressure balancing valves, etc., which is used to adjust the differential pressure valve opening, the use of pressure spool Changes to compensate for changes in descending resistance line, so that when conditions change substantially constant pressure can be maintained, it is the principle of flow within a certain range, you can effectively control the controlled system pressure constant, that is, when When the pressure system increases, through the valve automatically shuts trick, it can ensure the controlled system pressure increases on the contrary, when the pressure decreases, the valve automatically open a large, pressure remains constant. Independent pressure control valve itself: within the control of the automatic valve plug is turned off, the pressure across the valve exceeds a pre-set value, the valve automatically opens and automatically adjust the plug opening of the film in the sense of a role in maintaining the pressure at both ends of the valve the difference is relatively constant. Valves advantages: a comprehensive water balance of air conditioning water system, the water system balance in the debugging process can identify various system errors, such as incorrect connection devices, plumbing leaks, clogged filters, etc., conducive to the equipment fault diagnosis, repair, maintenance, thereby reducing system maintenance costs. Valves Installation Instructions: ① balancing valves can be installed either on the supply pipe to be installed in the return pipe. Generally, we recommend installation in the return pipe, especially for high-temperature loop to facilitate debugging, and more to be installed in the return pipe. ② recommended balancing valve and install shut-off valves, convenient subsequent commissioning and maintenance. ③ balancing valve on the manifold, should be installed in the direction of the water pump. ④ balancing valve can be installed horizontally, but also vertically. ⑤ opening of the indicators on the handle should face the commissioning of the line of sight and the direction to facilitate debugging. Before measuring connector on the body should not be an obstacle to avoid commissioning the instrument can not connect when debugging. When installed in the ceiling, should make the downward direction of the handle. Why should the dynamic balance valve: in the dynamic system, when some of the water flow loop is changed, for example, the user to adjust the valve to close the valve or the control valve changes in accordance with the independent operation of the load will cause pressure changes in the distribution system, thereby interfering with the other loop, so that other loop flows occur undue change. This hydraulic imbalance is random variation, dynamic, and therefore called dynamic imbalance. For dynamic imbalance in the system suitable site to install dynamic balancing valve, which can effectively avoid mutual interference between each user system, allowing the system to maintain water balance in the dynamic changes. Flow control valve at the factory preset according to the design flow is good, but also to the installation site settings. Set a good flow valve, as long as the valve operating pressure range of flow through the valve is pre-set flow rate. Dynamic balancing valve Applications: ① fixed horizontal branch pipe inlet flow system ② dynamic systems ................................................................................................... ................................................ American Tours valve (TOOE) Ordering Information: one, ① Flange dynamic flow balance valve product name and model ② ③ Flange dynamic flow balance valve diameter flange dynamic flow balance valve with an attachment so the temperature of our correct for your selection ④ Flange dynamic flow balance valve using a pressure ⑤ Flange dynamic flow balance valve using media. Second, if the valve flange Tours has a dynamic flow balance valve model, press the flange dynamic flow balance valve model directly to our sales department to order selected by the design. Third, when the occasion is very important or the environment is more complex when you try to provide design drawings and detailed parameters. |
Admin>>>
You are the 8067 visitor
Copyright © GuangDong ICP No. 10089450, American Tours valve (Taiwan) Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8067 visitor
Copyright © GuangDong ICP No. 10089450, American Tours valve (Taiwan) Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility